The emerging light therapy technology uses infrared energy to provide patients with a temporary increase in blood circulation, temporary relief of minor muscle and joint aches, pains and stiffness, relaxation of muscles and temporary relief of minor pain and stiffness associated with arthritis.
Wavelengths between 660 and 1,000 nm are used for this purpose. Light emitted by the laser diode penetrates deepest followed by the superluminous diode (SLDs) and then the light emitting diode (LEDs).
The Mettler Electronics Laser Sys*Stim™ comes with a 785 nm laser probe with visible blue LEDs that illuminate the treatment field. An optional SLD/LED cluster probe with 950 nm SLDs and 660 nm LEDs is also available. The Laser Sys*Stim allows the clinician to set treatment time, continuous/pulse modulation modes and laser output energy. All treatment parameters are displayed on the LED displays and controlled via the membrane keypad. There are holders integrated into the unit to store applicators when not in use. Laser output can also be adjusted via controls on the both laser and cluster applicators. A built-in sensor allows you to check the laser output to verify that it's working.
Operates on 110 10 240 Volts AC or 12 Volt battery (included) so you can take light therapy with you!
Weight: 5.5 pounds, (2.5kg)
Dimensions: 4.7" (12cm) high x 9.4" (24cm) deep x 9.4" (24cm) wide.
Specifications
| General Information: |
|
| Voltage: |
110 to 240 Volts AC |
| Frequency: |
50/60 Hz |
| Power: |
Less than 150 VA |
| Battery: |
Sealed lead acid, 12 Volt, 0.8 AH |
| Operation time on battery: |
Greater than 30 minutes |
| International standards: |
EN60601-1 1990 EN60601-2-22 1996 |
| Dimensions: |
9.4 in. (W) x 4.7 in. (H) x 9.4 in. (D) |
| Weight: |
5.5 lbs. |
| Laser output meter: |
Infrared photo sensor integrated into the top panel | |
|
Laser Applicator Specifications: |
|
| Wavelength: |
785 nm |
| Power: |
80 mW |
| Treatment area illumination: |
Three blue LED’s (470 nm) |
| Output activation: |
Capacitance switch on applicator handle |
| Beam spot: |
Elliptical beam spot 2.8 mm x 1.1 mm (elliptical beam area of = 9.2 mm²) at the aperture. |
| Divergence: |
Elliptical beam divergence 18 degrees and 7 degrees |
| Eye protection: |
Uvex Glass with a minimum of 80% attenuation in the wavelength range of 780 nm to 860 nm. The Uvex Glasses supplied with the unit meet these requirements. | |
| Laser Performance: |
|
|
Output power: Laser diode applicator Optional cluster applicator |
80 mW at 785nm 500 mW at 660/950nm
|
| Delivered energy: |
0.01 to 99.99 Joules |
|
Operation modes: Pulse mode: Pulse width: Laser: Cluster: |
Continuous and Pulsed
100 µs nominal 50% duty cycle |
|
Pulse frequency: A) B)
C) |
Continuous 10 Hz, 25 Hz, 50 Hz, 100 Hz, 250 Hz, 500 Hz, 1 kHz, 2 kHz, 5 kHz
Sweep from 10 to 5 kHz
|
| Timer |
0 to 99 minutes 59 seconds | |
| Optional Cluster Applicator Specifications: |
|
| SLD: |
Twelve 950 nm Super luminescent Diodes |
| LED: |
Seven 660 nm Light Emitting Diodes |
| Total Power |
500 mW |
| Treatment area illumination: |
The 660 nm LED’s are visible and illuminate treatment area |
| Output activation: |
Capacitance switch on applicator handle |
| Treatment area: |
3.4 cm² |
| Eye protection: |
Uvex Glass with a minimum of 80% attenuation in the wavelength range of 780 nm to 860 nm. The Uvex Glasses supplied with the unit meet these requirements. | |
|