Installs Virtually Anywhere - WingItsŪ allows for grab bar placement virtually anywhere at any point of the building or remodeling process. Use WingItsŪ Fastening System for dry wall, tile, acrylic or fiberglass tub surrounds. Installs in approx. 15 minutes, often requires no blocking or wood studs, and eliminates the need to tear open & reconstruct walls.
Residential Installations - In residential installations, it is preferable to have blocking if you are installing into 1/2" dry wall. (WingItsŪ alone with 1/2" drywall will only hold up to 250 pounds). Installation into ceramic tile, tub surrounds and marble, do not require blocking and have an 800lbs weight capacity.
Commercial Facilities - With 5/8" sheet rock, common in commercial facilities, no blocking is needed. This means there is no need to tear open and reconstruct existing walls, saving time and money.
 |
Solid Construction - Made from #304 (18/8 Stainless Steel) ADA/Building Codes - Exceeds all building codes and government guidelines. Waterproof Seal - 3M VHB adhesive tape creates a waterproof sealed between the flange and the wall. Clearance - Once inserted each wing assembly will springopen to approximately 2 -3/4" diameter. To ensure adequate clearance, a stud finder should be used to verify that there are NO STUDS within the area that the WingIt will be installed. WingIts Grab Bar Fastening system will exceed building code criteria for grab bars in the following wall substrates: *5/8" drywall - painted or wallpapered *1/2" or 5/8" drywall with tub surrounds. *1/2" or 5/8" drywall with tile, marble and all stone. *1/2" or 5/8" drywall with any panel types including fiberglass, faux marble, acrylic and plastics. *Multiple layers of drywall. *Plaster and lath. *1/4" acrylic/fiberglass surrounds. *1/4" acrylic/tub surrounds. *All masonry typeboards, with or without panels. |
NOTE: Never install any fasteners into wet or deteriorating walls! Do not install WingIts into bare 1/2" drywall when attempting to meet commercial building codes. FOR MAXIMUM SAFETY AND TO MEET ADA REQUIREMENTS, GRAB BARS SHOULD BE INSTALLED HORIZONTALLY 32-36" FROM THE FLOOR. Tools Required for Installation: regular and phillips screwdriver, drill, measuring tape, hammer or rubber mallet, 1/4" drill bit or punch, 1-1/4" carbide hole saw. Includes one (1) WingIt bolt (not a pair), 3 screws for affixing to the grab b ar.
|